10-year shelf life provides long-term reliability and cost savings on replacements.

Certified for comprehensive protection against a wide range of chemical, biological, radiological, and nuclear threats.

Used by military personnel, CBRN specialists, and special operations forces globally, ensuring trusted performance.

The NBC-17 SOF 40mm gas mask filter canister, in combination with a full-face mask, mouthpiece assembly, TAPR, or PAPR, reliably protects air passages against a wide range of harmful substances including CBRN agents.

The filters are produced with standard round threads according to STANAG 4155 (EN 148-1)- Rd 40x1/7". The filter components are made of hard plastic, resulting in a very robust product that is extremely durable against shock and impact damage in operational use.

IMPORTANT NOTE:

Due to the shorter threads, the NBC-17 SOF Filter is NOT compatible with the MB-90 PAPR unit.

NBC-17 SOF GAS MASK FILTER KEY FEATURES:

  • Compatible with standard 40mm NATO threaded respirators, which are widely available.
  • 10-year shelf life - save money long-term by not having to replace your filters every year.
  • Used by military personnel, CBRN specialists, and special operations forces all over the world.
  • Rated for A2B1E1K1P3 D R.
  • Certified by European agencies and has the “CE” symbol. Compliant under EN 14387+A1.

Technical Data

Technical Data Breathing Resistance in Pa
Diameter 90 mm @ flow rate 30l/min. EN 1) NBC-17 SOF 260 <200 @ flow rate 95l/min. EN 1) NBC-17 SOF 980 <800
Height 85 mm
Weight 205 g ±5%
Storage time 10 years (factory sealed)

 

Type and Class Particle filter efficiency @ flow rate 95l/m

A2 - organic gases and vapors P3 - particles Sodium Chloride NaCl (S) Paraffin oil (L) EN 99.95 99.95 NBC-17 SOF >99.999 >99.999
B1 - inorganic gases and vapors D- dust
E1 - acid gases and vapors R- reusable
K1 - ammonia and amines R- reusable

 

NBC-17 SOF GAS MASK FILTER APPLICATION:

The filter provides reliable protection against solid and liquid aerosols, smoke-producing substances, radioactive particles, bacteria, viruses, vapors of organic and inorganic acids, hydroxides, organic solvents with a boiling point above 65°C, ammonia, amines, acid gases, agricultural chemical combustion products, tear-producing agents, irritants, choking agents, blister and nerve agents, (e.g., bromoacetone, CS substance, organic compounds of arsenic, phosgene, hydrogen cyanide, cyanogen chloride, mustard gas, organophosphates) – sarin, IVA, VX and other toxic substances, (e.g., benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, phosgene, phosphoric acid and its organic derivatives, chloroacetic acid, nitric acid, aldehydes, mixtures of inorganic acids and organic substances).

Gas Mask Filter Lifetime:

Breakthrough time of a gas mask filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min. The approximate lifetime (usage time) of a filter may be calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

Gas Mask Filter Storage and Maintenance:

Each NBC-17 SOF gas mask filter is sealed in a plastic bag by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate conditions of -30 to +50°C and RH below 95%. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.

Gas Mask Filter Disposal:

After use, gas mask filters are considered special refuse. Dispose of them according to current waste treatment regulations. Dismantle from the respirator and dispose of as solid waste. Refer to local authority regulations for disposal advice and locations.

Testing Gas Concentration of Testing Gas Breakthrough Time in Minutes EN NBC-17 SOF DAC in Grams NBC-17 SOF
PPM MG/I
A2 Cyclohexane C₆H₁₂ 5000 17.5 35 37 19.425
B1 Chlorine Cl₂ 1000 15 20 >30 >2.700
Hydrogen Sulphide H₂S 1000 7.1 40 >60 >2.520
Hydrogen Cyanide HCN 1000 5.6 25 >60 >5.820
E1 Sulphur Dioxide SO₂ 1000 13.3 20 >30 >2.430
K1 Ammonia NH₃ 1000 3.5 40 >60 >1.260

 

Return Policy:

For MIRA Safety products, we adhere to the MIRA Safety return policy, prioritizing the safety and wellbeing of our customers above all else. Given the critical nature of the products we offer, and to ensure their integrity, we do not accept returns once items have shipped from our warehouse. This policy safeguards our customers, ensuring the PPE they receive is uncompromised and untampered.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

MIRA Safety

Mira Safety - Lightweight CBRN Gas Mask Filter NBC-17 SOF 40mm Thread - 10 Year Shelf Life

$4995

10-year shelf life provides long-term reliability and cost savings on replacements.

Certified for comprehensive protection against a wide range of chemical, biological, radiological, and nuclear threats.

Used by military personnel, CBRN specialists, and special operations forces globally, ensuring trusted performance.

The NBC-17 SOF 40mm gas mask filter canister, in combination with a full-face mask, mouthpiece assembly, TAPR, or PAPR, reliably protects air passages against a wide range of harmful substances including CBRN agents.

The filters are produced with standard round threads according to STANAG 4155 (EN 148-1)- Rd 40x1/7". The filter components are made of hard plastic, resulting in a very robust product that is extremely durable against shock and impact damage in operational use.

IMPORTANT NOTE:

Due to the shorter threads, the NBC-17 SOF Filter is NOT compatible with the MB-90 PAPR unit.

NBC-17 SOF GAS MASK FILTER KEY FEATURES:

Technical Data

Technical Data Breathing Resistance in Pa
Diameter 90 mm @ flow rate 30l/min. EN 1) NBC-17 SOF 260 <200 @ flow rate 95l/min. EN 1) NBC-17 SOF 980 <800
Height 85 mm
Weight 205 g ±5%
Storage time 10 years (factory sealed)

 

Type and Class Particle filter efficiency @ flow rate 95l/m

A2 - organic gases and vapors P3 - particles Sodium Chloride NaCl (S) Paraffin oil (L) EN 99.95 99.95 NBC-17 SOF >99.999 >99.999
B1 - inorganic gases and vapors D- dust
E1 - acid gases and vapors R- reusable
K1 - ammonia and amines R- reusable

 

NBC-17 SOF GAS MASK FILTER APPLICATION:

The filter provides reliable protection against solid and liquid aerosols, smoke-producing substances, radioactive particles, bacteria, viruses, vapors of organic and inorganic acids, hydroxides, organic solvents with a boiling point above 65°C, ammonia, amines, acid gases, agricultural chemical combustion products, tear-producing agents, irritants, choking agents, blister and nerve agents, (e.g., bromoacetone, CS substance, organic compounds of arsenic, phosgene, hydrogen cyanide, cyanogen chloride, mustard gas, organophosphates) – sarin, IVA, VX and other toxic substances, (e.g., benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, phosgene, phosphoric acid and its organic derivatives, chloroacetic acid, nitric acid, aldehydes, mixtures of inorganic acids and organic substances).

Gas Mask Filter Lifetime:

Breakthrough time of a gas mask filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min. The approximate lifetime (usage time) of a filter may be calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

Gas Mask Filter Storage and Maintenance:

Each NBC-17 SOF gas mask filter is sealed in a plastic bag by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate conditions of -30 to +50°C and RH below 95%. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.

Gas Mask Filter Disposal:

After use, gas mask filters are considered special refuse. Dispose of them according to current waste treatment regulations. Dismantle from the respirator and dispose of as solid waste. Refer to local authority regulations for disposal advice and locations.

Testing Gas Concentration of Testing Gas Breakthrough Time in Minutes EN NBC-17 SOF DAC in Grams NBC-17 SOF
PPM MG/I
A2 Cyclohexane C₆H₁₂ 5000 17.5 35 37 19.425
B1 Chlorine Cl₂ 1000 15 20 >30 >2.700
Hydrogen Sulphide H₂S 1000 7.1 40 >60 >2.520
Hydrogen Cyanide HCN 1000 5.6 25 >60 >5.820
E1 Sulphur Dioxide SO₂ 1000 13.3 20 >30 >2.430
K1 Ammonia NH₃ 1000 3.5 40 >60 >1.260

 

Return Policy:

For MIRA Safety products, we adhere to the MIRA Safety return policy, prioritizing the safety and wellbeing of our customers above all else. Given the critical nature of the products we offer, and to ensure their integrity, we do not accept returns once items have shipped from our warehouse. This policy safeguards our customers, ensuring the PPE they receive is uncompromised and untampered.