Structural Parameters |
EN ISO |
Specification |
Tolerance |
Weave |
EN 40161 |
Ripstop |
|
Global composition |
EN 40110 |
64% Lenzing FR/30% Meta-aramid/5% Para-aramid/1% Antistatic |
(+/- 3%) |
Weight (g/m2) |
EN 40339 |
220 |
(+/- 5%) |
Width (cm) |
EN 1773 |
155 |
(+/- 1%) |
Mechanical Qualities |
Method |
Values |
|
Tensile strength warp |
EN 13934-1 |
700 N |
|
Tensile strength weft |
EN 13934-1 |
500 N |
|
Tear strength warp |
EN 13937-2 |
20 N |
|
Tear strength weft |
EN 13937-2 |
20 N |
|
Pilling |
EN 12945-2 |
5 |
|
Abrasion |
EN 12947-2 |
>80.000 cycles |
|
Dimensional Stability to Washings |
Method |
Values |
|
Warp |
EN 25077 |
<3% |
|
Weft |
EN 25077 |
<3% |
|
Normative |
Level |
||
EN 11612 Protective clothing - Clothing to protect against heat and flame.
|
A1 A2 B1 C1 F1 |
||
EN 1149-3 Protective clothing - Electrostatic properties - Part 3: Test methods for measurement of charge decay
|
Pass |
||
Flame Retardant |
ISO 6940:2004 |
MOPP-1 Technical Product Testing:
samples
The details of the received sample are presented in Table 1.
Table 1: Received sample
Sample code MIRA |
Description by Customer |
received |
---|---|---|
21pq0928 |
AvEc-Ms-1-BATCH 1 |
04-05-2021 |
Test Method
The detailed description of the test procedures is presented in the Annex.
Results
The test results are presented in the Tables 2 and 3. Note that the test results are only applicable to the tested material, mentioned in Table 1.
Table 2: Laid droplet, diffusive flow HD, 10 g/m? (5% RH, 30°C, 24 hours, 1ul drops)
Sample code | penetrated amount (ug/cm?) |
---|---|
21PQ0928A | <0.05 |
21PQ0928B | <0.05 |
21PQ0928C | <0.05 |
Table 3: Vapour test, HD, target concentration 11 mg/m? (80% RH, 30°C, 6 hours, wind speed 5 m/s)
Sample code | Challenge (mg/m3) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|
21PQ0928A | 12 | 0.33 | <3.7 |
21PQ0928B | 12 | 0.33 | <3.8 |
21PQ0928C | 12 | 0.34 | <3.7 |
Samples
The details of the received samples are presented in Table 1.
Table 1: Received samples
Sample code | Description by Customer | received |
---|---|---|
20PQ2305 | Outer shell: 0QAMEU0476, open ripstop with DWR&FR finish, new | 04-11-2020 |
20PQ2306 | Filter layer: ALLGO0002N, sphere filter, 345 g/m2 3 ply filter with 04-11-2020 non woven white and sphere active carbon and black knit, new | 04-11-2020 |
20PQ2307 | Outer shell: 0AAMEU0476, open ripstop with DWR&FR finish,pie 10x washed ISO 6330, 4N, tumbler dry low temperature | 04-11-2020 |
20PQ2308 | Filter layer: ALL60002N, sphere filter, 345 g/m2 3 ply filter with non woven white and sphere active carbon and black knit, 10x washed ISO 6330, 4N, tumbler dry low temperature | 04-11-2020 |
Test Method
The detailed description of the test procedures is presented in the Annex.
Results
The test results are presented in the Tables 2 through 9. Note that the test results are only applicable to the tested materials, mentioned in Table 1.
Table 2: Laid droplet, convective flow 5 m/s, HD, 10 g/m? (80% RH, 30°C, 24 hours, 1)
Sample code | State | Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|
20PQ2306/20PQ2305A | New | 2.2 | 482 |
20PQ2306/20PQ2305B | New | 2.2 | 347 |
20PQ2306/20PQ2305C | New | 2.3 | 485 |
20PQ2308/20PQ2307A | Washed10x | 1.3 | 181 |
20PQ2308/20PQ2307B | Washed10x | 1.3 | 268 |
20PQ2308/20PQ2307C | Washed10x | 1.5 | 292 |
Table 3: Vapour test 5 m/s, HD, target concentration 11 mg/m? (80% RH, 30°C, 6 hours)
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 11 | 2.2 | 65 |
20PQ2306/20PQ2305B | New | 11 | 2.6 | 80 |
20PQ2306/20PQ2305C | New | 11 | 2.8 | 107 |
20PQ2308/20PQ2307A | Washed10x | 11 | 1.3 | 25 |
20PQ2308/20PQ2307B | Washed10x | 11 | 1.3 | 14 |
20PQ2308/20PQ2307C | Washed10x | 11 | 1.5 | 28 |
Table 4: Vapour test 1 m/s, HD, target concentration 55 mg/m? (80% RH, 30°C, 6 hours)
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 56 | 0.11 | <12 |
20PQ2306/20PQ2305B | New | 56 | 0.11 | <12 |
20PQ2306/20PQ2305C | New | 56 | 0.9 | <14 |
20PQ2308/20PQ2307A | Washed10x | 56 | 0.7* | <20 |
20PQ2308/20PQ2307B | Washed10x | 56 | 0.7* | <20 |
20PQ2308/20PQ2307C | Washed10x | 56 | 0.7* | <20 |
Due to equipment restrictions, the minimum flow of 50 ml/min (= 0.07 cm/s) was applied, instead of the required 42-48 ml/min.
Table 5: Vapour test 5 m/s, GD, target concentration 11 mg/m® (80% RH, 30°C, 6 hours
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 11 | 1.8 | 60 |
20PQ2306/20PQ2305B | New | 11 | 1.9 | 51 |
20PQ2306/20PQ2305C | New | 11 | 1.9 | 68 |
20PQ2308/20PQ2307A | Washed10x | 11 | 1.6 | 38 |
20PQ2308/20PQ2307B | Washed10x | 11 | 1.5 | 48 |
20PQ2308/20PQ2307C | Washed10x | 11 | 1.5 | 29 |
Table 6: Vapour test 1 m/s, GD, target concentration 55 mg/m3 (80% RH, 30°C, 6 hours)
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 55 | 0.07 | <14 |
20PQ2306/20PQ2305B | New | 55 | 0.10 | <10 |
20PQ2306/20PQ2305C | New | 55 | 0.10 | <10 |
20PQ2308/20PQ2307A | Washed10x | 55 | 0.07* | <16 |
20PQ2308/20PQ2307B | Washed10x | 55 | 0.07* | <16 |
20PQ2308/20PQ2307C | Washed10x | 55 | 0.07* | <16 |
Due to equipment restrictions, the minimum flow of 50 ml/min (= 0.07 cm/s) was applied, instead of the required 42-48 ml/min.
Table 7: Laid droplet 0.5 m/s diffusive flow HD, 10 g/m? 30°C, 24 hours, 1ul drops)
Sample code | State | Penetrated amount (ug/cm2) |
---|---|---|
20PQ2306/20PQ2305A | New | <0.08 |
20PQ2306/20PQ2305B | New | 1.0 |
20PQ2306/20PQ2305C | New | <0.08 |
20PQ2308/20PQ2307A | Washed10x | <0.08 |
20PQ2308/20PQ2307B | Washed10x | <0.08 |
20PQ2308/20PQ2307C | Washed10x | <0.08 |
Table 8: Laid droplet 0.5 m/s, diffusive flow GD, 10 g/m? (80% RH,30°C, 24 hours, 1ul drops)
Sample code | State | Penetrated amount (ug/cm2) |
---|---|---|
20PQ2306/20PQ2305A | New | 0.53 |
20PQ2306/20PQ2305B | New | 0.32 |
20PQ2306/20PQ2305C | New | 0.14 |
20PQ2308/20PQ2307A | Washed10x | 0.12 |
20PQ2308/20PQ2307B | Washed10x | <0.06 |
20PQ2308/20PQ2307C | Washed10x | 0.10 |
Table 9: Laid droplet, diffusive flow LVAP, VX, 10 g/m? (5% RH, 30°C, 24 hours, 1ul drops)
Sample code |
State |
Penetrated amount (ug/cm2) |
---|---|---|
20PQ2306/20PQ2305A |
New |
1.0 |
20PQ2306/20PQ2305B |
New |
0.93 |
20PQ2306/20PQ2305C |
New |
0.21 |
20PQ2308/20PQ2307A |
Washed10x |
0.30 |
20PQ2308/20PQ2307B |
Washed10x |
0.41 |
20PQ2308/20PQ2307C |
Washed10x |
0.48 |
Product Care Instructions:
- PREPARE ITEM BY ZIPPING UP ALL POCKETS
- WASH IN WARM WATER ONLY
- NO DETERGENT
- TUMBLE DRY UNTIL ITEM IS THOROUGHLY DRY
MOPP Suit Size Guide:
The MOPP-1 CBRN Protective suit is available in three different sizes (available as size pairs):
- Small - Medium (SM/MD)
- Large - Extra Large (LG/XL)
- 2X Large -3X Large (2XL/3XL)
SM/MD | LG/XL | 2XL/3XL | ||||
Chest Girth- measures over the biggest bulk of the breast just under the armpit | 78-86 | 86-94 | 94-102 | 102-110 | 110-118 | 118-129 |
Waist Girth- measures the smallest part of the upper body | 66-74 | 74-82 | 82-90 | 90-98 | 98-106 | 106-117 |
Person's Height- measures the total length from the head to ground | 156-164 | 164-172 | 172-180 | 180-188 | 188-196 | 196-204 |
***Dimensions in cm |
Return Policy:
For MIRA Safety products, we adhere to the MIRA Safety return policy, prioritizing the safety and wellbeing of our customers above all else. Given the critical nature of the products we offer, and to ensure their integrity, we do not accept returns once items have shipped from our warehouse. This policy safeguards our customers, ensuring the PPE they receive is uncompromised and untampered.