Structural Parameters |
EN ISO |
Specification |
Tolerance |
Weave |
EN 40161 |
Ripstop |
|
Global composition |
EN 40110 |
64% Lenzing FR/30% Meta-aramid/5% Para-aramid/1% Antistatic |
(+/- 3%) |
Weight (g/m2) |
EN 40339 |
220 |
(+/- 5%) |
Width (cm) |
EN 1773 |
155 |
(+/- 1%) |
Mechanical Qualities |
Method |
Values |
|
Tensile strength warp |
EN 13934-1 |
700 N |
|
Tensile strength weft |
EN 13934-1 |
500 N |
|
Tear strength warp |
EN 13937-2 |
20 N |
|
Tear strength weft |
EN 13937-2 |
20 N |
|
Pilling |
EN 12945-2 |
5 |
|
Abrasion |
EN 12947-2 |
>80.000 cycles |
|
Dimensional Stability to Washings |
Method |
Values |
|
Warp |
EN 25077 |
<3% |
|
Weft |
EN 25077 |
<3% |
|
Normative |
Level |
||
EN 11612 Protective clothing - Clothing to protect against heat and flame.
|
A1 A2 B1 C1 F1 |
||
EN 1149-3 Protective clothing - Electrostatic properties - Part 3: Test methods for measurement of charge decay
|
Pass |
||
Flame Retardant |
ISO 6940:2004 |
MOPP-1 Technical Product Testing:
samples
The details of the received sample are presented in Table 1.
Table 1: Received sample
Sample code MIRA |
Description by Customer |
received |
---|---|---|
21pq0928 |
AvEc-Ms-1-BATCH 1 |
04-05-2021 |
Test Method
The detailed description of the test procedures is presented in the Annex.
Results
The test results are presented in the Tables 2 and 3. Note that the test results are only applicable to the tested material, mentioned in Table 1.
Table 2: Laid droplet, diffusive flow HD, 10 g/m? (5% RH, 30°C, 24 hours, 1ul drops)
Sample code | penetrated amount (ug/cm?) |
---|---|
21PQ0928A | <0.05 |
21PQ0928B | <0.05 |
21PQ0928C | <0.05 |
Table 3: Vapour test, HD, target concentration 11 mg/m? (80% RH, 30°C, 6 hours, wind speed 5 m/s)
Sample code | Challenge (mg/m3) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|
21PQ0928A | 12 | 0.33 | <3.7 |
21PQ0928B | 12 | 0.33 | <3.8 |
21PQ0928C | 12 | 0.34 | <3.7 |
Samples
The details of the received samples are presented in Table 1.
Table 1: Received samples
Sample code | Description by Customer | received |
---|---|---|
20PQ2305 | Outer shell: 0QAMEU0476, open ripstop with DWR&FR finish, new | 04-11-2020 |
20PQ2306 | Filter layer: ALLGO0002N, sphere filter, 345 g/m2 3 ply filter with 04-11-2020 non woven white and sphere active carbon and black knit, new | 04-11-2020 |
20PQ2307 | Outer shell: 0AAMEU0476, open ripstop with DWR&FR finish,pie 10x washed ISO 6330, 4N, tumbler dry low temperature | 04-11-2020 |
20PQ2308 | Filter layer: ALL60002N, sphere filter, 345 g/m2 3 ply filter with non woven white and sphere active carbon and black knit, 10x washed ISO 6330, 4N, tumbler dry low temperature | 04-11-2020 |
Test Method
The detailed description of the test procedures is presented in the Annex.
Results
The test results are presented in the Tables 2 through 9. Note that the test results are only applicable to the tested materials, mentioned in Table 1.
Table 2: Laid droplet, convective flow 5 m/s, HD, 10 g/m? (80% RH, 30°C, 24 hours, 1)
Sample code | State | Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|
20PQ2306/20PQ2305A | New | 2.2 | 482 |
20PQ2306/20PQ2305B | New | 2.2 | 347 |
20PQ2306/20PQ2305C | New | 2.3 | 485 |
20PQ2308/20PQ2307A | Washed10x | 1.3 | 181 |
20PQ2308/20PQ2307B | Washed10x | 1.3 | 268 |
20PQ2308/20PQ2307C | Washed10x | 1.5 | 292 |
Table 3: Vapour test 5 m/s, HD, target concentration 11 mg/m? (80% RH, 30°C, 6 hours)
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 11 | 2.2 | 65 |
20PQ2306/20PQ2305B | New | 11 | 2.6 | 80 |
20PQ2306/20PQ2305C | New | 11 | 2.8 | 107 |
20PQ2308/20PQ2307A | Washed10x | 11 | 1.3 | 25 |
20PQ2308/20PQ2307B | Washed10x | 11 | 1.3 | 14 |
20PQ2308/20PQ2307C | Washed10x | 11 | 1.5 | 28 |
Table 4: Vapour test 1 m/s, HD, target concentration 55 mg/m? (80% RH, 30°C, 6 hours)
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 56 | 0.11 | <12 |
20PQ2306/20PQ2305B | New | 56 | 0.11 | <12 |
20PQ2306/20PQ2305C | New | 56 | 0.9 | <14 |
20PQ2308/20PQ2307A | Washed10x | 56 | 0.7* | <20 |
20PQ2308/20PQ2307B | Washed10x | 56 | 0.7* | <20 |
20PQ2308/20PQ2307C | Washed10x | 56 | 0.7* | <20 |
Due to equipment restrictions, the minimum flow of 50 ml/min (= 0.07 cm/s) was applied, instead of the required 42-48 ml/min.
Table 5: Vapour test 5 m/s, GD, target concentration 11 mg/m® (80% RH, 30°C, 6 hours
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 11 | 1.8 | 60 |
20PQ2306/20PQ2305B | New | 11 | 1.9 | 51 |
20PQ2306/20PQ2305C | New | 11 | 1.9 | 68 |
20PQ2308/20PQ2307A | Washed10x | 11 | 1.6 | 38 |
20PQ2308/20PQ2307B | Washed10x | 11 | 1.5 | 48 |
20PQ2308/20PQ2307C | Washed10x | 11 | 1.5 | 29 |
Table 6: Vapour test 1 m/s, GD, target concentration 55 mg/m3 (80% RH, 30°C, 6 hours)
Sample code | State | Challenge (mg/33) |
Velocity through sample (cm/s) |
Penetrated dose (mg.min/m3) |
---|---|---|---|---|
20PQ2306/20PQ2305A | New | 55 | 0.07 | <14 |
20PQ2306/20PQ2305B | New | 55 | 0.10 | <10 |
20PQ2306/20PQ2305C | New | 55 | 0.10 | <10 |
20PQ2308/20PQ2307A | Washed10x | 55 | 0.07* | <16 |
20PQ2308/20PQ2307B | Washed10x | 55 | 0.07* | <16 |
20PQ2308/20PQ2307C | Washed10x | 55 | 0.07* | <16 |
Due to equipment restrictions, the minimum flow of 50 ml/min (= 0.07 cm/s) was applied, instead of the required 42-48 ml/min.
Table 7: Laid droplet 0.5 m/s diffusive flow HD, 10 g/m? 30°C, 24 hours, 1ul drops)
Sample code | State | Penetrated amount (ug/cm2) |
---|---|---|
20PQ2306/20PQ2305A | New | <0.08 |
20PQ2306/20PQ2305B | New | 1.0 |
20PQ2306/20PQ2305C | New | <0.08 |
20PQ2308/20PQ2307A | Washed10x | <0.08 |
20PQ2308/20PQ2307B | Washed10x | <0.08 |
20PQ2308/20PQ2307C | Washed10x | <0.08 |
Table 8: Laid droplet 0.5 m/s, diffusive flow GD, 10 g/m? (80% RH,30°C, 24 hours, 1ul drops)
Sample code | State | Penetrated amount (ug/cm2) |
---|---|---|
20PQ2306/20PQ2305A | New | 0.53 |
20PQ2306/20PQ2305B | New | 0.32 |
20PQ2306/20PQ2305C | New | 0.14 |
20PQ2308/20PQ2307A | Washed10x | 0.12 |
20PQ2308/20PQ2307B | Washed10x | <0.06 |
20PQ2308/20PQ2307C | Washed10x | 0.10 |
Table 9: Laid droplet, diffusive flow LVAP, VX, 10 g/m? (5% RH, 30°C, 24 hours, 1ul drops)
Sample code |
State |
Penetrated amount (ug/cm2) |
---|---|---|
20PQ2306/20PQ2305A |
New |
1.0 |
20PQ2306/20PQ2305B |
New |
0.93 |
20PQ2306/20PQ2305C |
New |
0.21 |
20PQ2308/20PQ2307A |
Washed10x |
0.30 |
20PQ2308/20PQ2307B |
Washed10x |
0.41 |
20PQ2308/20PQ2307C |
Washed10x |
0.48 |
Product Care Instructions:
- PREPARE ITEM BY ZIPPING UP ALL POCKETS
- WASH IN WARM WATER ONLY
- NO DETERGENT
- TUMBLE DRY UNTIL ITEM IS THOROUGHLY DRY
MOPP Suit Size Guide:
The MOPP-1 CBRN Protective suit is available in three different sizes (available as size pairs):
- Small - Medium (SM/MD)
- Large - Extra Large (LG/XL)
- 2X Large -3X Large (2XL/3XL)
SM/MD | LG/XL | 2XL/3XL | ||||
Chest Girth- measures over the biggest bulk of the breast just under the armpit | 78-86 | 86-94 | 94-102 | 102-110 | 110-118 | 118-129 |
Waist Girth- measures the smallest part of the upper body | 66-74 | 74-82 | 82-90 | 90-98 | 98-106 | 106-117 |
Person's Height- measures the total length from the head to ground | 156-164 | 164-172 | 172-180 | 180-188 | 188-196 | 196-204 |
***Dimensions in cm |